Most approaches to cutting SIEM costs work the same way: they force you to guess which data future investigations will need. Data that’s filtered or dropped using an upstream pipeline is gone. Meanwhile, data that’s routed to low-cost object storage is often too slow to query mid-incident.
The fix is to stop asking the SIEM to do both jobs. With Monad as a router, you can filter the data that the SIEM needs for detections and keep it in the SIEM for only as long as the rules look back. Meanwhile, Monad also sends a complete, full-fidelity copy of the data to Hydrolix, which is designed for long-term, always hot queries on petabyte-scale data. With this approach, you can use the SIEM for detections and keep data in Hydrolix with a long-term retention policy that ensures investigations always have the data they need. This approach solves the cost and data availability issues that come with other approaches to managing SIEM data.
The latest Hydrolix Hot Data Episode on the partnership between Hydrolix and Monad covers the challenge of keeping too much data in a SIEM and how to solve it. Federico Rodriguez, Distinguished Software Engineer at Hydrolix, and Valerie Worman, Head of Marketing at Monad, met with host Josh Robinson. According to Rodriguez, “Detection gets kept where it is today [in the SIEM], you can keep your analysts, and where retention happens becomes a separate question.”
Compute Detection Windows in the SIEM, Keep Investigation Windows Long-Term
Detection windows can be computed. Combine the lookback window on your detections with enough margin for triaging alerts and possibly for detection rules that haven’t been written yet. If your longest detection windows are 30 days, you know exactly how long you need to retain data for your rules to work. If you’re using a SIEM for detection, you can set your retention window as tightly as possible to manage costs.
Investigation windows, on the other hand, are unpredictable. IBM’s 2026 breach report puts the mean time to identify a breach at 183 days, with another 64 to contain it. The retention window needs to be sufficiently long to contain all the data you need for incident analysis, but you don’t know ahead of time whether you set the retention window long enough. You don’t want to find out too late that you set the retention window too short to properly investigate an incident.
When the ambiguity of settting a retention window goes up against the cost pressure of storing data in a SIEM long-term, teams are forced to make difficult decisions. But full-fidelity data at the length of an investigation window doesn’t belong in the SIEM. It should go in a cost-effective solution designed for long-term storage and high data availability regardless of the age of the data.
If you use the SIEM for both jobs, both windows are collapsed into one. You get charged the high cost of a SIEM’s detection window for your investigation windows, and that usually results in shorter retention windows to control costs, increasing the risk that you won’t have the data when you need it. “Where that cost sits ends up deciding your security posture,” Worman said. “We want teams to decide where their data goes based on what it’s worth to them, not what it costs to store.”
Store just enough data in the SIEM to cover detection rules to get the most out of your SIEM while controlling costs. Meanwhile, a security data layer holds the full-fidelity record long-term, without cost pressure to delete or archive data that you might need for an investigation.
Filter the SIEM Feed Without Losing the Data
Monad is a security data pipeline that makes the split possible. It sits upstream of the SIEM, collects from roughly 370 sources, normalizes and deduplicates events, adds context, and routes to more than 40 destinations. “Nobody wakes up and is like, I really want to write parsers,” Worman said. Monad handles that.
The SIEM feed stays intact. Monad copies data rather than moving it, so detections get the data they need while the full record also goes to Hydrolix, which acts as the security data layer.
| What gets routed | Where it goes | How long it stays | How fast it answers |
| The sources and fields detections consume | The SIEM | As long as the longest rule lookback, plus triage margin | Immediately, on the data still in the window |
| A full-fidelity copy of everything (every event, no sampling) | Hydrolix | 15 months by default, longer on request | Immediately, across the whole 15-month window |
| Archival copies required by policy | S3 or equivalent object storage | Whatever the mandate requires | Only after a restore, so it's rarely queried |
With a security data layer holding a full-fidelity copy, you can aggressively trim the data you send to the SIEM. Monad puts the ceiling on that trimming at up to 70% of the data that’s typically sent to a SIEM. “They’re getting more comfortable being aggressive on how they’re filtering, because they know they’ve still got this full fidelity copy sitting at Hydrolix,” Worman said. “It becomes less about insurance and more about a design choice.” As Rodriguez put it, “If the filter is reversible, you can be a lot more creative with it.”
The security data layer also handles spikes in traffic without fidelity loss. “In an incident, volume doesn’t creep up. It suddenly spikes,” Worman said. “That’s the point in time when you can’t afford to lose the data. It’s probably the most important data you’re going to collect.” Monad buffers and retries when a destination slows, applies backpressure (slowing intake rather than discarding events), and resumes from the last good record it received, so a recovered connection leaves no duplicates or gaps. Monad puts the design target at 10x log spikes with no capacity planning on the team’s side. Meanwhile, Hydrolix is designed to handle tens of millions of log lines per second with a 5-10 second time to glass for queries, such as when it provided CDN monitoring for FOX during the Super Bowl.
Retain Full-Fidelity Data Without a Cold Tier
Many teams route data to archives or to unstructured data lakes that aren’t designed for fast data retrieval. That’s a problem for analysts that are under pressure to identify an incident or contain the impact of a breach. When traffic spikes and an alert goes off, you can immediately investigate any high-volume log sources that aren’t being stored at full fidelity in the SIEM by querying the underlying security data layer.
That data availability should hold even if you’re querying data from six months or a year ago, when you need to quickly reconstruct how long an incident has been happening and which services are impacted.
Hydrolix keeps full-fidelity data hot for 15 months by default, with longer retention available on request. There is no rehydration step. Hydrolix uses columnar storage with up to 50x compression while maximizing the performance of commodity object storage, so the cost of retention is equivalent to archiving the data, with none of the tradeoffs in terms of data availability.
Evaluate Your Security Data Layer on Query Time
When evaluating a security data layer, it’s critical to look beyond the per-GB cost. Archived data is cheap for a reason—it’s not easily accessible. The real test is whether your storage solution provides both cost-effectiveness and data availability. The best way to check that is with a long-lookback query on production-scale data, ideally using the tools your analysts prefer.
For Monad and Hydrolix, that meant a production-scale test using Hydrolix connector for Splunk. With the connector, Hydrolix tables are queryable from inside Splunk through the Hydrolix Search for Splunk app, using the hdxsearch command and standard SPL. “Analysts don’t need to move,” Worman said. “You don’t need to get rid of your Splunk analysts.”
Hydrolix and Monad tested the arrangement with RAD, an MSSP (managed security service provider) partner. “Testing security is not something people like to do,” Rodriguez said, “so in order to make things realistic we were able to get real Palo Alto data and look at it in a controlled environment.” Monad routed those firewall logs into Hydrolix, and the query ran from inside Splunk. “We got good results in 1.6 seconds for a production enterprise grade amount of data,” Rodriguez said.
Lower cost per gigabyte on archived data is easy to demonstrate. Lower cost per gigabyte on data an analyst can query mid-incident without rehydration is the bigger challenge, and the test with RAD demonstrated that data was available in seconds without moving a detection out of Splunk.
Prove It on a High-Volume Source Without Touching Detections
A pilot takes a few weeks. Pick a data source that you already route to SIEM, route it through Monad to both the SIEM and Hydrolix, and leave the SIEM feed exactly as it is. Nothing needs to move out of the SIEM and no detections change. Once you’ve proven that the architecture works, you can aggressively trim data you’re sending to your SIEM while extending the availability of all your data for long-term investigations.
- Watch the latest episode of Hot Data.
- Interested in trying out Hydrolix with Monad? Talk with an expert to learn more.